Delta Electronics AH500 — 12.4.1 CPU Modules

Chapter 12 Troubleshooting 12-53 Error code Description CPU Status LED indicator status ERROR BUS FAULT 16#9B27 An error occurs when COM2 communicates with slave 7 by Modbus. Continue Keep Keep 16#9B28 An error occurs when COM2 communicates with slave 8 by Modbus. Continue Keep Keep 16#9B29 An error occurs when COM2 communicates with slave 9 by Modbus. Continue Keep Keep 16#9B2A An error occurs when COM2 communicates with slave 10 by Modbus. Continue Keep Keep 16#9B2B An error occurs when COM2 communicates with slave 11 by Modbus. Continue Keep Keep 16#9B2C An error occurs when COM2 communicates with slave 12 by Modbus.

Continue Keep Keep 16#9B2D An error occurs when COM2 communicates with slave 13 by Modbus. Continue Keep Keep 16#9B2E An error occurs when COM2 communicates with slave 14 by Modbus. Continue Keep Keep 16#9B2F An error occurs when COM2 communicates with slave 15 by Modbus. Continue Keep Keep 16#9B30 An error occurs when COM2 communicates with slave 16 by Modbus. Continue Keep Keep 16#9B31 An error occurs when COM2 communicates with slave 17 by Modbus. Continue Keep Keep 16#9B32 An error occurs when COM2 communicates with slave 18 by Modbus. Continue Keep Keep 16#9B33 An error occurs when COM2 communicates with slave 19 by Modbus.

Continue Keep Keep 16#9B34 An error occurs when COM2 communicates with slave 20 by Modbus. Continue Keep Keep 16#9B35 An error occurs when COM2 communicates with slave 21 by Modbus. Continue Keep Keep 16#9B36 An error occurs when COM2 communicates with slave 22 by Modbus. Continue Keep Keep 16#9B37 An error occurs when COM2 communicates with slave 23 by Modbus. Continue Keep Keep 16#9B38 An error occurs when COM2 communicates with slave 24 by Modbus. Continue Keep Keep 16#9B39 An error occurs when COM2 communicates with slave 25 by Modbus. Continue Keep Keep 16#9B3A An error occurs when COM2 communicates with slave 26 by Modbus.

Continue Keep Keep 16#9B3B An error occurs when COM2 communicates with slave 27 by Modbus. Continue Keep Keep 16#9B3C An error occurs when COM2 communicates with slave 28 by Modbus. Continue Keep Keep 16#9B3D An error occurs when COM2 communicates with slave 29 by Modbus. Continue Keep Keep 16#9B3E An error occurs when COM2 communicates with slave 30 by Modbus. Continue Keep Keep 16#9B3F An error occurs when COM2 communicates with slave 31 by Modbus. Continue Keep Keep 16#9B40 An error occurs when COM2 communicates with slave 32 by Modbus. Continue Keep Keep 16#9B41 COM2 receives no response from slave 1 by Modbus. Continue Keep Keep 16#9B42 COM2 receives no response from slave 2 by Modbus.

Continue Keep Keep 16#9B43 COM2 receives no response from slave 3 by Modbus. Continue Keep Keep 16#9B44 COM2 receives no response from slave 4 by Modbus. Continue Keep Keep