Delta AH500 — 6.5.2 Explanation of Jump Instructions

Chapter 6 Applied Instructions API 0402 Symbol: Explanation: 1. When the condition is met, the execution of the program jumps to END in the program. 2. Function blocks and interrupt tasks do not support the instruction. Besides, the instruction can not be between the instruction FOR and the instruction NEXT. 3. When the instruction GOEND is executed, the instructions skipped are not executed, the data in all devices is unchanged, and the states of all devices are also unchanged. 6-143 Instruction code Operand Function GOEND ─ Jumping to END Pulse instruction 16-bit instruction (1 step) 32-bit instruction - AH500 -