Delta AH500 — 6.11.2 Explanation of Basic Instructions

AH500 Programming Manual 6.11.2 Explanation of Basic Instructions Symbol: D : Device which is reset Bit/Word Explanation: 1. When the instruction RST is driven, the action of the device specified is as follows. 2. If the instruction RST is not executed, the status of the device specified is unchanged. 3. The instruction supports the direct output. When X0.0 is ON, Y0.5 is set to OFF. Example:

6-228 API Instruction code Operand Function 1000 RST D Resetting the contact or clearing the register Device X Y M S T C HC D L SM SR E PR K 16# “$” DF D              Pulse instruction 16-bit instruction (3 steps) 32-bit instruction - AH500 - Device status Bit The coil and the contact are set to OFF. T, C, and HC The timer and the counter are reset to 0, and the coil and the contact are set to OFF. Word The value is cleared to 0.