Kaiyi — 2.2.8 Refresh Time of Special Auxiliary Relays

AH500 Programming Manual 2-42 Special auxiliary relay Refresh time SM1670 Users set SM1670 to ON and reset it to OFF. SM1671~SM1672 The flag is refreshed when the instruction WRITE is executed. SM1673 SM1673 is refreshed when the instruction WRITE is executed and an error occurs. SM1674 SM1674 is refreshed when the instruction WRITE is executed and there is a response timeout. SM1675 Users set SM1675 to ON and reset it to OFF. SM1676~SM1677 The flag is refreshed when the instruction WRITE is executed. SM1678 SM1678 is refreshed when the instruction WRITE is executed and an error occurs. SM1679 SM1679 is refreshed when the instruction WRITE is executed and there is a response timeout.

SM1680 Users set SM1680 to ON and reset it to OFF. SM1681~SM1682 The flag is refreshed when the instruction RPASS is executed. SM1683 SM1683 is refreshed when the instruction RPASS is executed and an error occurs. SM1684 SM1684 is refreshed when the instruction RPASS is executed and there is a response timeout. SM1685 Users set SM1685 to ON and reset it to OFF. SM1686~SM1687 The flag is refreshed when the instruction RPASS is executed. SM1688 SM1688 is refreshed when the instruction RPASS is executed and an error occurs. SM1689 SM1689 is refreshed when the instruction RPASS is executed and there is a response timeout. SM1690 Users set SM1690 to ON and reset it to OFF.

SM1691~SM1692 The flag is refreshed when the instruction RPASS is executed. SM1693 SM1693 is refreshed when the instruction RPASS is executed and an error occurs. SM1694 SM1694 is refreshed when the instruction RPASS is executed and there is a response timeout. SM1695 Users set SM1695 to ON and reset it to OFF. SM1696~SM1697 The flag is refreshed when the instruction RPASS is executed. SM1698 SM1698 is refreshed when the instruction RPASS is executed and an error occurs. SM1699 SM1699 is refreshed when the instruction RPASS is executed and there is a response timeout. SM1700 Users set SM1700 to ON and reset it to OFF.

SM1701~SM1702 The flag is refreshed when the instruction RPASS is executed. SM1703 SM1703 is refreshed when the instruction RPASS is executed and an error occurs. SM1704 SM1704 is refreshed when the instruction RPASS is executed and there is a response timeout. SM1705 Users set SM1705 to ON and reset it to OFF. SM1706~SM1707 The flag is refreshed when the instruction RPASS is executed. SM1708 SM1708 is refreshed when the instruction RPASS is executed and an error occurs. SM1709 SM1709 is refreshed when the instruction RPASS is executed and there is a response timeout. SM1710 Users set SM1710 to ON and reset it to OFF.

SM1711~SM1712 The flag is refreshed when the instruction RPASS is executed. SM1713 SM1713 is refreshed when the instruction RPASS is executed and an error occurs.