Commodore Amiga 1000 — Commodore Amiga 1000 Hardware Reference Manual PDF Download

NOTE Even though the A channel is disabled, we use it in our logic function and preload the data register. Disabling a channel simply turns off the memory fetches for that channel; all other operations are still performed, only from a constant value stored in the channel's data register An alternative but more subtle way of accomplishing the same thing is to use an A shift of five, a first word mask of all ones, and a last word mask with the rightmost nine bits set to zero. All other registers remain the same. NOTE Be sure to load the blitter immediate data registers only after setting the shift count in BLTCON0/BLTCON1, as loading the data registers first will lead to unpredicTable results.

For instance, if the last person left BSHIFT to be "4", and I load BDATA with "1" and then change BSH1 to "2", the resulting BDATA that is used is "1 loading one of the data registers "draws" the data through the machine and shifts it. DESCENDING MODE Our standard memory copy blit works fine if the source does not overlap the destination. If we want to move an image one row down (towards increasing addresses), however, we run into a problem - we overwrite the second row before we get a chance to copy it! The blitter has a special mode of operation - descending mode - that solves this problem nicely. Descending mode is turned on by setting bit one of BLTCON1 (defined as BLITREVERSE).

If you use descending mode the address pointers will be decremented by two (bytes) instead of incremented by two for each word fetched. In addition, the modulo values will be subtracted rather than added. Shifts are then towards the left, rather than the right, the first word mask masks the last word in a row (which is still the first word fetched, and the last word mask masks the first word in a row. Thus, for a standard memory copy, the only difference in blitter setup (assuming no shifting or masking) is to initialize the address pointer registers to point to the last word in a block, rather than the first word.

The modulo values, blit size, and all other parameters should be set the same. NOTE This differs from predecrement versus postincrement in the 68000, where an address register would be initialized to point to the word after the last, rather than the last word. Descending mode is also necessary for area filling, which will be covered in a later section. - 176 Blitter Hardware -