Commodore Amiga 1000 — Commodore Amiga 1000 Hardware Reference Manual PDF Download

BIT MAP OF REGISTER CRA REG# NAME UNUSED SPMODE INMODE LOAD RUNMODE OUTMODE PBON START E CRA unused 0=input 0=02 1=force 0=cont. 0=pulse 0=PB60FF 0=stop unused 1=output 1=CNT load 1=one- 1=toggle 1-PB60N 1=start (strobe) shot | | All unused register bits are unaffected by a write and forced to 0 on a read. CONTROL REGISTER B: BIT NAME FUNCTION 0 START 1=start Timer B, 0=stop Timer B. This bit is automatically reset (=0) when underflow occurs during one-shot mode. 1 PBON 1=Timer B output on PB7, 0= PB7 is normal operation. 2 OUTMODE 1=toggle, 0=pulse. RUNMODE 1=one-shot mode, 0=continuous mode.

4 LOAD 1=force load (this is a strobe input, there is no data storage; bit 4 will always read back a zero and writing a 0 has no effect.) 6,5 INMODE Bits CRB6 and CRB5 select one of four possible input modes for Timer B, as follows: CRB6 CRB5 Mode Selected ---- ---- -------------------------- 0 0 Timer B counts 02 pulses 0 1 Timer B counts positive CNT transitions 1 0 Timer B counts Timer A underflow pulses 1 1 Timer B counts Timer A underflow pulses while CNT pin is held high. 7 ALARM 1=writing to TOD registers sets Alarm 0=writing to TOD registers sets TOD clock. Reading TOD registers always reads TOD clock, regardless of the state of the Alarm bit. - 328 Appendix F -