initialize a location register. It is assumed that the user has already created the correct Copper instruction list at location "mycoplist." ; ; Install the copper list ; LEA CUSTOM,a1 ; a1 = address of custom chips LEA MYCOPLIST(pc),a0 ; Address of our copper list MOVE.L a0,COP1LC(a1) ; Write whole longword address MOVE.W COPJMP1(a1),d0 ; Causes copper to load PC from COP1LC ; ; Then enable copper and raster dma ; MOVE.W #(DMAF SETCLR!DMAF_COPPER!DMAF_RASTER!DMAF_MASTER),DMACON(a1) ; Now, if the contents of COP1LC are not changed, every time vertical blanking occurs the Copper will restart at the same location for each subsequent video screen.

This forms a repeatable loop which, if the list is correctly formulated, will cause the displayed screen to be stable. STOPPING THE COPPER No stop instruction is provided for the Copper. To ensure that it will stop and do nothing until the screen display ends and the program counter starts again at the top of the instruction list, the last instruction should be to WAIT for an event that cannot occur. A typical instruction is to WAIT for VP = $FF and HP = $FE. An HP of greater than $E2 is not possible. When the screen display ends and vertical blanking starts, the Copper will automatically be pointed to the top of its instruction list, and this final WAIT instruction never finishes.

You can also stop the Copper by disabling its ability to use DMA for retrieving instructions or placing data. The register called DMACON controls all of the DMA channels. Bit7, COPEN, enables Copper DMA when set to 1. For information about controlling the DMA, see Chapter 7, "System Control Hardware." - 26 Coprocessor Hardware -