Chapter 8 Load Cell Module AS02LC Step 7: Put a load on the load cell (adjustment point 2). For multi-point adjustment, repeat this step. This example uses a 1 kg weight. Step 8: the calibration is complete. A characteristic curve is shown below. Weight 8_ 10 kg 1 k g Point Digital value 1000 10000 0 Adjusting two points 8-23