AS Series Module Manual 8.5.2 Troubleshooting Procedure _8 8-36 Error A↔ D LED ERROR LED Description Code indicator indicator - When power-on, the module is not detected by CPU module. OFF Blinking once or twice and after 2 seconds, it blinks repeatedly Description Procedure The external voltage is abnormal. Ensure the power supply is functioning correctly. Hardware failure Return the module to the factory for repair. The driver board is abnormal. Return the module to the factory for repair. The weight measured by CH1 exceeds the maximum weight that can be measured, or the voltage of SEN is incorrect. Check the signal received by CH1 and its wiring.
The weight measured by CH1 exceeds the maximum weight that can be measured. Check the parameters of the related weight values for CH1. CH1 is adjusted incorrectly. Check the adjusted weight value and the adjustment steps for CH1. The weight measured by CH2 exceeds the maximum weight that can be measured, or the voltage of SEN is incorrect. Check the signal received by CH2 and its wiring. The weight measured by CH2 exceeds the maximum weight that can be measured. Check the parameters of the related weight values for CH2. CH2 is adjusted incorrectly. Check the adjusted weight value and the adjustment steps for CH2. When power-on, the module is not detected by CPU module.
Check if the connection between module and CPU module is working. If not, connect again.