Delta Electronics — 9.6.3 Remote IO Application (AS-FCOPM)

Chapter 9 Serial Communication Module AS00SCM 9.6.3 Remote IO Application (AS-FCOPM) This example shows other series PLC, AH10COPM-5A, as a CANopen Master that controls four IO modules on the right side of AS00SCM-A that acts as a CANopen Slave. (You can use this method to connect to a 3 rd party PLC.) Step 1 Use AS300 to connect to AS00SCM-A through AS Remote Communication (RTU mode) and then use HWCONFIG to scan and download the parameters. If the Card 2 LED is blinking normally, with no error messages, and no need to download the PLC programs, the device power can be turned off. Refer to Section 9.4.1.1 for reference.

9_ 9-65 Device Function AS300 Scan and download AS00SCM-A (RTU mode), right side module configurations AS00SCM-A + AS-FCOPM CANopen Slave AHCPU530-EN + AH10COPM-5A CANopen Master AS16AN10R-A 16 Digital outputs AS16AM01N-A 16 Digital inputs AS04DA-A 4 Analog channels for output AS04AD-A 4 Analog channels for input