Delta Electronics — 12.2.4. Special Designed Instrucitons

AS Series Module Manual 12.2.4. Special Designed Instrucitons Special designed instructions for the positioning modules are listed below: Note: Refer to section 6.15 in AS Series Programming Manual for more information on the instrucions listed above.

12-8 Instruction code Pulse API Function 16-bit 32-bit instruction 1400 FROM DFROM  Reading data from the control register in an extension module 1401 TO DTO  Writing data into the control register in an extension module 1402 PUCONF DPUCONF  Setting output control parameters of PU module 1403 PUSTAT – – Reading PU module output state 1404 – DPUPLS – PU module pulse output (no acceleration) 1405 – DPUDRI – Relative position output of PU module (with acceleration and deceleration) 1406 – DPUDRA – Absolute addressing output of PU module (with acceleration and deceleration) 1407 – DPUZRN – PU module homing 1408 – DPUJOG – PU module jog output 1409 – DPUMPG – PU module MPG output 1410 – DPUCNT – High-speed counter function of PU module 12