Delta Electronics — 12.4.3. State Codes (Axis 1 - 4)

Chapter 12 Positioning Module AS02/04PU 12.4 Troubleshooting 12.4.1. Error Codes 12 12.4.2. Troubleshooting Procedure 12.4.3. State Codes (Axis 1 - 4) 12-21 Error A↔ D LED ERROR LED Description Code indicator indicator 16#1802 Hardware failure OFF Blinking Description Procedure Hardware failure Return the module to the factory for repair. State Code Axis Axis Description Byte # 1-2 3-4 0 Error flag Axis 1 Axis 3 1 The output is active. 2 The output has stopped working. 3 The instruction execution is complete.

4 Pulse in positive direction not allowed 5 Pulse in negative direction not allowed 6 Current position value overflow 7 Pulse direction (positive or negative) 8 Error flag Axis 2 Axis 4 9 The output is active. 10 The output has stopped working. 11 The instruction execution is complete. 12 Pulse in positive direction not allowed 13 Pulse in negative direction not allowed 14 Current position value overflow 15 Pulse direction (positive or negative)