Delta Electronics — 6.27.2 Explanation of CANopen Communication Instructions

AS Series Programming Manual 7. The COPRW instruction only supports the Delta Special Driver & AS Remote Mode and CANopen DS301 in the hardware configuration setting (HWCONFIG in ISPSoft). _6 8. Most of the parameters in Delta ASDA-A2 are displayed in the decimal format. You can convert the parameters into index addresses, see the example below. 0 is a fixed value for the sub index address. Example: The index address of PX-YY=0x2000 + ( X ) + YY P2-10 = 0x2000 + ( 0x0002 ) + 0x000A = 0x220A P5-04 = 0x2000 + ( 0x0005 ) + 0x0004 = 0x2504 P1-44 = 0x2000 + ( 0x0001 ) + 0x002C = 0x212C 9. Most of the parameters in Delta inverter are also displayed in the decimal format.

Use the following formula to convert the parameters. 6-922