Delta Electronics — 6.27.2 Explanation of CANopen Communication Instructions

AS Series Programming Manual _6 6-932 original point. 7 = Homing in the reverse direction; ORGP: ON > OFF, as the original point. 8 = Current position is the original point. Homing method: 9~A 9 = Homing in the forward direction; the collision point is the original point. A = Homing in the reverse direction; the collision point is the original point.