Chapter 6 Applied Instructions 6_ Symbol Slave : Servo slave station number Source : From which E-CAM chart to start downloading Len : The length of the E-CAM chart CAddr : From which address to start storing E-CAM chart in the servo Done : Downloading complete flag Explanation 1. Slave is where you store the downloaded E-CAM chart; the supported slave station ranges from 1 to 8. After the downloading is complete, the DONE flag is ON. If the slave station number you are using is out of the supported range, the instruction is NOT executed. And the Err (error) flag is ON. 2.
Source is where you specify from which E-CAM chart to start downloading; the supported E-CAM chart length is from 1 to 16. If the E-CAM chart number you are using is out of the supported length, the instruction is NOT executed. And 6-939 API Instruction Operand Description 2813 ECAMD Slave ~ ErrCode Downloading E-CAM chart to the Slave Device X Y M S T C HC D FR SM SR E K 16# “$” F Slave Source Len CAddr Done Err ErrCode BOOL WORD DWORD LWORD UINT INT DINT LINT REAL LREAL TMR CNT STRING Data type Slave Source Len CAddr Done Err ErrCode Pulse Instruction 16-bit instruction 32-bit instruction - AS -