Delta Electronics — 6.27.2 Explanation of CANopen Communication Instructions

AS Series Programming Manual Symbol Slave : Servo slave station number Command source for encoder of the master Smode : axis From which address to start storing E-CAM CAddr : chart in the servo CLen : Specified E-CAM chart length for executing Number of pulses for the master’s E-CAM to RPuu : rotate a full 360 cycle Cmode : Engaging condition Number of pulses for E-CAM to wait before WbPuu : engaging for the first time (32-bit value) OutT : Disengaging condition Number of pulses for E-CAM to wait before CaPuu : disengaging (32-bit value) Number of pulses for E-CAM to wait before CwPuu : engaging again (32-bit value) ORate : Output ratio for E-CAM chart (32-bit value) _6 Done : Downloading complete flag Err : Error flag ErrCode : Error code Explanation 1.

This instruction is for setting up the E-CAM related parameters for the first time or setting up the E-CAM chart before the first engagement. If you need to modify the E-CAM chart during engaging, you need to use instruction ECAMC (API2816) instead. 2. Slave is the servo slave station, ranging from 1 to 8. If the slave station number you are using is out of the supported range, the instruction is NOT executed. And the Err (error) flag is ON. After modifying and the specified servo slave station responds correctly, the DONE flag is ON. 3. Smode is where you can set the command source for encoder of the master axis; the options are as shown below.