AS Series Programming Manual Path 4 : When the disengaged condition is established (P5-88, U=4), the status is Engaged → Pre-engaged. The lead pulse is determined by P5-92 (available for FM V1.006sub04 or later). Path 5: When the disengaged condition is established (P5-88, U=1, 2, 6) or the E-CAM function is disabled (P5-88, X=0), the status is Engaged → Stop. 。 7. MIPuu is wherer you can find the number of pulses received by the specified Slave from the Master. The unit is per this value does NOT refreshed either. user unit (PUU) of the servo. This value is shown accoridng to the servo parameter P5-86. When the instruction stops, 8.
SOPuu is wherer you can find the number of pulses outputted by the specified Slave. The unit is per user unit (PUU) of the servo. This value is shown accoridng to the servo parameter CMD_O. When the instruction stops, this value does NOT refreshed either. 9. If the Err (error) flag is ON, refer to the definitions below. _6 6-948 ErrCode Description 0001 This slave station number is NOT in the supported range. 0004 No response from the slave. 0005 Error message sent from the slave while downloading or setting up. 0006 The PLC is NOT in the Delta Special Driver & AS Remote Mode nor in the Delta Special Driver & CANopen DS301 Mode. 0007 The slave is not initiated.