Delta Electronics — 6.27.3 Frequently asked questions in Delta special CANopen communication and Troubleshooting

AS Series Programming Manual 3. CAddr is the starting address where to store the E-CAM chart in the servo; the supported setting range is from 0 to 794. If the starting address you are using is out of the supported range, the instruction is NOT executed. And the Err (error) flag is ON. PLC sets the servo parameter P5-81 (start address of data array). 4. CLen is the specified E-CAM chart length for executing; its setting range is from 5 to 720. E-CAM chart is divided into CLen and the chart should include CLen +1 data.

The servo supports 1 st ~ 800 th space; if the starting address is 501 and set the CLen to 400, this arrangement takes 902 (501+401) space which exceeds the 800 th space, the instruction is NOT executed and the Err (error) flag is ON. PLC sets the servo parameter P5-82. Write this parameter when E-CAM stops (P5-88, X=0). 5. Once executing this instruction, it clears the Done flag first and then sends the modification request. After modifying the E-CAM parameters and the specified servo slave station responds correctly, the DONE flag is ON. If any error occurs from the slaves, the Err (error) flag is ON.

If you need to modify the E-CAM starting address and length, you need to wait for one scan time before executing this instruction again. 6. If the Err (error) flag is ON, refer to the definitions below. _6 6-950 ErrCode Description 0001 This slave station number is NOT in the supported range. 0002 This E-CAM chart number is NOT in the supported range. 0003 This downloading address (CAddr) or length (CLen) is NOT in the supported range. 0004 No response from the slave. 0005 Error message sent from the slave while downloading or setting up. 0006 The PLC is NOT in the Delta Special Driver & AS Remote Mode nor in the Delta Special Driver & CANopen DS301 Mode.