Delta Electronics — 2.2.7 Special Auxiliary Relays (SM)

Chapter 2 Devices 2_ 2-15 AS300 Series AS200 Series Latched Attribute Default OFF STOP RUN SM Function    ON RUN STOP when Power On”, use this flag to activate the 26th module on the right-side of the CPU module. *SM256 When selecting “Manual + Flags” in “I/O allocation setting when Power On”, use this flag to activate the 27th module on the right-side of the CPU module. ○ ○ – – – Y R/W OFF *SM257 When selecting “Manual + Flags” in “I/O allocation setting when Power On”, use this flag to activate the 28th module on the right-side of the CPU module.

○ ○ – – – Y R/W OFF *SM258 When selecting “Manual + Flags” in “I/O allocation setting when Power On”, use this flag to activate the 29th module on the right-side of the CPU module. ○ ○ – – – Y R/W OFF *SM259 When selecting “Manual + Flags” in “I/O allocation setting when Power On”, use this flag to activate the 30th module on the right-side of the CPU module. ○ ○ – – – Y R/W OFF *SM260 When selecting “Manual + Flags” in “I/O allocation setting when Power On”, use this flag to activate the 31st module on the right-side of the CPU module.

○ ○ – – – Y R/W OFF *SM261 When selecting “Manual + Flags” in “I/O allocation setting when Power On”, use this flag to activate the 32nd module on the right-side of the CPU module.

○ ○ – – – Y R/W OFF SM270 Reversing the input direction for MPG 1 flag (X0.0/X0.1) ○ ○ OFF OFF – N R/W OFF SM271 Reversing the input direction for MPG 2 flag (X0.2/X0.3) ○ ○ OFF OFF – N R/W OFF SM272 Reversing the input direction for MPG 3 flag (X0.4/X0.5) ○ ○ OFF OFF – N R/W OFF SM273 Reversing the input direction for MPG 4 flag (X0.6/X0.7) ○ ○ OFF OFF – N R/W OFF SM274 Reversing the input direction for MPG 5 flag (X0.8/X0.9) ○ ○ OFF OFF – N R/W OFF SM275 Reversing the input direction for MPG 6 flag (X0.10/X0.11) ○ ○ OFF OFF – N R/W OFF SM221 Enable daylight saving time ○ ○ – – – H R OFF SM281 Reversing the input direction for high-speed counter 1 flag ○ ○ OFF OFF – N R/W OFF SM282 Reversing the input direction for high-speed counter 2 flag ○ ○ OFF OFF – N R/W OFF SM283 Reversing the input direction for high-speed counter 3 flag ○ ○ OFF OFF – N R/W OFF SM284 Reversing the input direction for high-speed counter 4 flag ○ ○ OFF OFF – N R/W OFF SM285 Reversing the input direction for high-speed counter 5 flag ○ ○ OFF OFF – N R/W OFF SM286 Reversing the input direction for high-speed counter 6 flag ○ ○ OFF OFF – N R/W OFF SM287 Reversing the input direction for high-speed counter 7 flag ○ ○ OFF OFF – N R/W OFF SM288 Reversing the input direction for high-speed counter 8 flag ○ ○ OFF OFF – N R/W OFF SM291 Clearing the input point for high-speed counter 1 flag ○ ○ OFF OFF – N R/W OFF SM292 Clearing the input point for high-speed counter 2 flag ○ ○ OFF OFF – N R/W OFF