Chapter 6 Applied Instructions 6.15.2 Explanation of Module Instructions Symbol 6_ m 1 : CPU module number or the remote extension module number m 2 : Order numbers of the extension number m 3 : Control register number D 1 : Device where the data is stored D 2 : Device where the error code is stored n : Data length Explanation 1. This instruction reads data from the control register in an extension module. 2. The value in m 1 must be between 0 – 16. Zero represents the CPU module, and 1 – 16 represent the extension modules.
6-405 API Instruction code Operand Function 1400 D FROM P m1, m2, m3, D1, D2, n Reading data from the control register in an extension module Device X Y M S T C HC D FR SM SR E K 16# “$” F m1 m2 m3 D1 D2 n BOOL WORD DWORD LWORD UINT INT DINT LINT REAL LREAL TMR CNT STRING Data type m1 m2 m3 D1 D2 n Pulse instruction 16-bit instruction 32-bit instruction AS AS AS