Chapter 6 Applied Instructions Example When X0.0 is ON, the FACOS instruction finds the arccosine of the floating-point number in (D1, D0) and stores it in (D11, D10). The FDEG instruction converts the arccosine value in (D11, D10) into degrees, and stores the conversion result in (D21, D20). The DINT instruction converts the degrees value in (D21, D20) into an integer, and stores the conversion result in (D31, D30). The BCD instruction converts the integer in (D31, D30) into a binary-coded decimal value, and stores the conversion result in Y0.15–Y0.0.
R180 D21~D20 R1 D0 R3.141592 D11~D10 FACOS FDEG 6_ Floating-point number Floating-point number Floating-point number BCD DINT D31~D30 0 1 0 8 Y1.15~Y1.0 180 Binary value Binary-coded decimal value Additional remarks 1. The floating-point number specified by the operand S must be between –1.0 to 1.0. If the floating-point number is not in the range, the instruction is not executed, SM0 is ON, and the error code in SR0 is 16#2003. 2. If the value in S exceeds the range of values that can be represented by floating-point numbers, the instruction is not executed, SM0 is ON, and the error code in SR0 is 16#2013. 6-467