AS Series Programming Manual 5. Id_Ip sets the communication station address (Mac ID) of the slave DMV or network IP. Address is the communication address where DMV detection result is read. Length is the length of the read detection data. 6. See the explanation of the values of ErrCode in the table below. Example 1 Mode=0 Only set1 is used to trigger the DMV detection and receiving of DMV response data. See the sequence control diagram below. En Start1 _6 Shoot1 Ready Com. port Ok Explanation of the timings: The DMVSH instruction is enabled.
Set Start1 to On to notify the instruction to send the output signal Shoot1 (ON for about 10ms) and notify DMV to enable the detection function. After DMV receives the trigger message, Ready is set from On to Off. Shoot1 is cleared to Off automatically by the PLC. 6-622 Error code Description Correction 16#0001 The specified communication port is incorrect. Specify a new communication port number. 16#0002 DMV response fault Check the communication address 16#0003 No response from DMV Check if the cable is connected properly or DMV has been enabled. 16#0004 Waiting for the response from DMV; DMV detection cannot be enabled repeatedly. Modify the timing of enabling DMV detection.
send receive