Chapter 5: Advanced Serverboard Setup 3. Align pin 1 of the CPU with pin 1 of the socket. Once aligned, care- fully place the CPU into the socket. Do not drop the CPU on the socket, move the CPU horizontally or verti- cally or rub the CPU against the socket or against any pins of the socket, which may damage the CPU and/or the socket . 4. With the CPU inserted into the socket, inspect the four corners of the CPU to make sure that it is properly installed and fl ush with the socket. Then, gently lower the silver CPU retention plate into place. 5. Carefully press the CPU socket lever down until it locks into its re- tention tab.

For a dual-processor system, repeat these steps to install another CPU into the CPU#2 socket or install to all four sockets for a quad-CPU confi guration Installing the Heatsink The use of active type heatsinks are recommended. Connect the heatsink fans to the appropriate fan headers on the serverboard. To install the heatsinks, please follow the installation instructions included with your heatsink package (not included). 5-3