Tuning ASDA-B3 5.3.5 Setting the bandwidth response level (stiffness) When the inertia is fixed and you increase the bandwidth response level (P2.031), the servo’s 5 bandwidth increases as well. If resonance occurs, lower the parameter value by one or two bandwidth response levels (you should adjust the bandwidth response level according to the actual situation). For instance, if the value of P2.031 is 30, you can reduce the bandwidth response level to 28. When you adjust the value of this parameter, the servo drive automatically adjusts the corresponding parameters, such as P2.000 and P2.004.
Servo bandwidth Level increases 84 Hz 26 Hz 5 Inertia ratio (P1.037) Position Command Response Feedback Before After Time Time Figure 5.3.5.1 Adjust the bandwidth response level 5-18 Command Position Response Feedback