Delta Electronics — 6.1 Selecting the operation mode

ASDA-B3 Operation Mode 6.1 Selecting the operation mode This servo drive provides three basic operation modes: Position, Speed, and Torque. The available communication modes are CANopen, DMCNET, and EtherCAT. For the basic 6 operation mode, you can choose from Single mode, Dual mode, and Multi-mode. The following table lists all the available modes. 6-3 Mode Short name Code Description Single mode Position mode (Terminal block input) PT 00 The servo drive receives the Position command and commands the motor to run to the target position. The Position commands are communicated through the terminal block and the signal type is pulse.

Position mode (Register input) PR 01 The servo drive receives the Position command and commands the motor to run to the target position. The Position commands are issued from the internal registers (100 sets in total). Select the register number with DI signals or through communication. Speed mode S 02 The servo drive receives the Speed command and commands the motor to run at the target speed. The Speed commands are issued from the internal registers (3 sets in total) or by analog voltage (-10V to +10V) which is communicated through the terminal block. Select the command with DI signals.

Speed mode (No analog input) Sz 04 The servo drive receives the Speed command and commands the motor to run at the target speed. The Speed command can only be issued from the internal registers (3 sets in total) instead of through the external terminal block. Select the command with DI signals. Torque mode T 03 The servo drive receives the Torque command and commands the motor to run with the target torque. The Torque commands are issued from the internal registers (3 sets in total) or by analog voltage (-10V to +10V) which is communicated through the terminal block. Select the command with DI signals.

Torque mode (No analog input) Tz 05 The servo drive receives the Torque command and commands the motor to run with the target torque. The Torque command can only be issued from the internal registers (3 sets in total) instead of through the external terminal block. Select the command with DI signals. Dual mode PT-S 06 Switch PT and S modes with DI signals. PT-T 07 Switch PT and T modes with DI signals. PR-S 08 Switch PR and S modes with DI signals. PR-T 09 Switch PR and T modes with DI signals. S-T 0A Switch S and T modes with DI signals. PT-PR 0D Switch PT and PR modes with DI signals. Communication mode 0B DMCNET mode Operates with the communication mode for PLC.

0C CANopen mode EtherCAT mode Multi-mode PT-PR-S 0E Switch PT, PR, and S modes with DI signals. PT-PR-T 0F Switch PT, PR, and T modes with DI signals.