Operation Mode ASDA-B3 6.5.2 Speed / Torque dual mode Speed / Torque dual mode includes only S-T. You control the Speed command with the external 6 analog voltage and the internal parameters (P1.009 - P1.011), which you select with DI.SPD0 and DI.SPD1. Similarly, the source of the Torque command can be the external analog voltage or the internal parameters (P1.012 - P1.014), and is selected by DI.TCM0 and DI.TCM1. The switch between Speed and Torque modes is controlled by the DI.S-T (0x19) signal. The timing diagram is shown as follows.
S-T ON OFF ON SPD0 - 1 valid SPD0 - 1 invalid SPD0 - 1 invalid TCM0 - 1 valid TCM0 - 1 valid TCM0 - 1 invalid Speed mode Torque mode Torque mode In Torque mode (DI.S-T is on), you select the Torque command with DI.TCM0 and DI.TCM1. When switching to Speed mode (DI.S-T is off), you select the Speed command with DI.SPD0 and DI.SPD1. The motor operates according to the Speed command. When DI.S-T is on, it returns to the Torque mode. Refer to the introduction of single mode for the DI signal and the selected commands for each mode. 6-32