Delta Electronics — 7.1.3.1 Homing methods

Motion Control ASDA-B3 If the ORG signal at the start point is triggered (high, Start point 3), the servo operates at low speed (second speed setting) in the forward direction until the ORG signal switches to low. Next, the servo reverses to look for the Z pulse. When the servo finds 7 the Z pulse, it decelerates to a stop, completing the homing procedure. (b) If you set the servo to look for the Z pulse in the forward direction or not to look for the Z pulse (this is similar to method (a) mentioned above), refer to the timing diagram above. 5. Referencing the current position as the origin. This method uses the motor’s current position as the reference origin.

As long as the homing procedure is triggered and the motor remains still, then coordinate positioning is complete. Motor End DI:0x27 SHOM 7-18