Delta Electronics — 7.1.3.5 Write command

Motion Control ASDA-B3 7.1.3.5 Write command The PR mode includes a Write command. It can write constants, parameters, data arrays, and monitoring variables to the specified parameters or data arrays. You can write a parameter to a 7 specified path in the PR mode screen in ASDA-Soft (see Figure 7.1.3.5.1).  INS is an interrupt command that interrupts the previous motion command. Refer to Section 7.1.6 for more details.  AUTO command automatically loads and executes the next PR once the current PR completes.  ROM command writes parameters to both RAM and EEPROM at the same time.

Writing to non-volatile memory function is also available; however, frequent usage shortens the life of the EEPROM.  DLY is the delay time that is determined by the shared PR parameters. Once a Jump command is issued, the servo drive starts counting the delay time. Table 7.1.3.5.1 shows the bit functions when a Write command is in operation. Figure 7.1.3.5.1 PR mode Write command screen in ASDA-Soft 7-30 Writing Target Data source Parameter Constant Data array Parameter - Data array - Monitoring variables