Delta Electronics — 7.1.3.6 Index Position command

Motion Control ASDA-B3 7.1.3.6 Index Position command The PR mode includes an Index Position command, which creates an indexing coordinate system. This command positions the motor within the indexing coordinates. Unlike other 7 feedback positions in global coordinate system, the Index Position command is able to divide the total moving distance of one index into the number of paths required by the application (see Figure 7.1.3.6.1). When using the Index Position command for motor operation in single direction (or mostly in the same direction), if the motor position exceeds the range, absolute position or position counter overflow occurs. Refer to the setting in Chapter 10.

You can start the index positioning in the Index Coordinates Setting Wizard in the PR mode screen in ASDA-Soft (see Figure 7.1.3.6.2). As shown in the example, the start PR path is set to 1, the path number is set to 10, and the total moving distance is 100000 PUU. When you click OK , the software automatically writes position command 0 PUU to PR#01, 10000 PUU to PR#02, 20000 PUU to PR#03, and so on up to PR#08. When the index position reaches 80000 PUU, it automatically returns to 0 PUU. In addition, you can modify the index position in each PR path as needed, as shown in Figure 7.1.3.6.3.  INS is an interrupt command that interrupts the previous motion command. Refer to Section 7.1.6.

 OVLP is an overlap command that allows the next PR command to overlap the command currently being executed when decelerating. If you use this function, setting the delay time to 0 is suggested. Refer to Section 7.1.6.  DIR sets the rotation direction with options of forward rotation (always runs forward), reverse rotation (always runs backward), and the shortest distance. The movement is illustrated in Figure 7.1.3.6.4.  S_LOW is the speed unit with options of 0.1 r/min or 0.01 r/min.  AUTO is a command that automatically loads and executes the next PR path when the current PR completes.  ACC / DEC is the acceleration / deceleration time determined by the shared PR parameters.

 SPD is the target speed determined by the shared PR parameters.  DLY is the delay time determined by the shared PR parameters. It is defined by a command from the controller. The servo starts counting the delay time once reaching the target position.  Position command is the target position of each index segment. Note that the setting range must be smaller than the total index moving distance (P2.052). Table 7.1.3.6.1 shows the bit functions when an Index Position command is in operation. If you use the index function, execute homing first in order to create the coordinate system so that the origin of the motor’s feedback position and that of the motor’s index position can be identical.

If you do not execute homing, AL237 occurs. 7-32