Motion Control ASDA-B3 7.1.6 PR procedure execution flow The ASDA-B3 updates the command status every 1 ms. Figure 7.1.6.1 illustrates the PR procedure execution flow and how the servo drive deals with PR commands. Once a PR 7 procedure is triggered, it goes through three units, which are PR queue, PR executor, and motion command generator. Integrates multiple commands (sequence, interrupt, or overlap commands). Outputs the integrated motion commands. Speed Time Figure 7.1.6.1 PR execution flow in the ASDA-B3 Trigger mechanism The trigger mechanism is as mentioned in Section 7.1.5. There are three trigger methods. A PR procedure is executed as long as a trigger signal is output.
When two different trigger methods are used for one PR procedure within the same ms, the priority is as follows: DI trigger (DI.CTRG) > PR command trigger register (P5.007) > Rising-edge event trigger (Event ↑) > Falling-edge event trigger (Event↓). Within this ms, commands with higher priority are executed first and then the lower priority commands are arranged in the next ms. If three trigger commands are generated in the same ms, the third is not added to the PR queue. 7-46 Priority High DI:CTRG P5.007 Event( ) Event( ) Low PR queue Every 1 ms, issues the waiting lead PR to PR executor no matter whether the executor has completed the commands or not.
New lead PR replaces the PR in the executor. Every 1 ms, issues the waiting lead PR to PR executor no matter whether the executor has completed the commands or not. New lead PR replaces the PR in the executor. PR executor Sends the paths set with motion commands to the generator (Speed Cmd, Position Cmd). Completes jump and write commands. Within 1 ms, it completes at least 20 consecutive paths with interruption functions and without delay. Motion command generator