Delta Electronics — 7.2.2 High-speed position capture function (Capture)

ASDA-B3 Motion Control PR#1 (I) PR#2 (I) PR#3 (I) Write Write Write DLY=[0] 0 ms P5.039=0x2030 DLY=[0] 0 ms DLY=[0] 0 ms P5.036=100 P5.038=3 7 PR#5 (I) PR#6 (I) PR#7 (I) Write Write Speed DLY=[10] 1 ms P1.019=0x0001 DLY=[0] 0 ms P5.039=0x203B 50 rpm Acc=[0] 3.33 ms Dec=[0] 3.33 ms DLY=[0] 0 ms Figure 7.2.2.3 PR path with application of high-speed capture function CAP axis position (PUU) Time DI7: CAP DO:

[0x16] CAP_OK PR path #51 #1 - 6 #50 #50 Figure 7.2.2.4 Application example for high-speed capture function 7-65 PR#4 (I) Write DLY=[0] 0 ms P5.076=0 PR#50 (I) PR#51 Position Speed DLY=[0] 0 ms 50000 PUU CAP 100 rpm DLY=[0] 0 ms 50 rpm Acc=[0] 3.33 ms Dec=[0] 3.33 ms Data array #100 0 0 0 45678 45678 50345 26789 45678 #101 0 12501 12501 12501 50345 #102 0 0 26789 26789 56789 10 000 PUU 1000 0 PUU (3)