Delta Electronics — 8.1 Parameter definitions

Parameters ASDA-B3 8.1 Parameter definitions The servo drive parameters are divided into eight groups. The first character after the start code 8 P is the group number and the following three characters are the parameter indicator. The communication address is the combination of the group number and the three-digit number, expressed in hexadecimal. The parameter groups are: Group 0: Monitoring parameters (Example: P0.xxx) Group 1: Basic parameters (Example: P1.xxx) Group 2: Extension parameters (Example: P2.xxx) Group 3: Communication parameters (Example: P3.xxx) Group 4: Diagnosis parameters (Example: P4.xxx) Group 5: Motion control parameters (Example: P5.xxx) Group 6:

PR parameters (Example: P6.xxx) Group 7: PR parameters (Example: P7.xxx) Control mode description: PT: Position control (command input through terminal block) PR: Position control (command sent from internal register) S: Speed control T: Torque control Special symbol description: 8-2 Icon of parameter Description property ★ Read-only parameter. Can only read the value of the parameter. For example, P0.000, P0.010, and P4.000. ▲ Parameter cannot be changed when servo is in Servo On status. For example, P1.000 and P1.046. ● Parameter changes become valid after power cycling. For example, P1.001 and P3.000. ■ Parameter resets to its default value after power cycling. For example, P3.006.