Delta Electronics — P2.xxx Extension parameters

ASDA-B3 Parameters 8 Settings: When the Torque command exceeds P2.104, the speed controller gain is switched from PI to P in order to reduce response overshoot. Settings: Use this parameter to adjust the bandwidth when auto-tuning. If the value is larger, the bandwidth after auto-tuning is higher, but if the bandwidth margin is insufficient, it may cause machine jitter. If the value is smaller, the bandwidth after auto-tuning is lower, but the response is slower. Value (dB) Higher bandwidth Moderate bandwidth Lower bandwidth Frequency P2.105 > 11 (Hz) P2.105 = 11 P2.105 Settings: Use this parameter to adjust the maximum allowable overshoot when auto-tuning.

The overshoot range is set for either the user or the machine. If the value is larger, the maximum overshoot allowed by auto-tuning is greater, but the response is faster. If the value is smaller, the maximum overshoot allowed by auto-tuning is smaller, but the response is slower. 8-91 Address: 02D0H P2.104 P/PI torque switching command condition 02D1H Default: 800 Control mode: PT / PR / S / Sz Unit: % Setting range: 1 - 800 Format: DEC Data size: 16-bit Address: 02D2H P2.105 Automatic gain adjustment level 1 02D3H Default: 11 Control mode: PT / PR Unit: - Setting range: 1 - 21 Format: DEC Data size: 16-bit Address: 02D4H P2.106 Automatic gain adjustment level 2 02D5H Default:

2000 Control mode: PT / PR Unit: pulse Setting range: 1 - 50331648 Format: DEC Data size: 32-bit