Delta Electronics — P4.xxx Diagnosis parameters

ASDA-B3 Parameters 8 Settings: Manually adjust the offset. The function must be enabled by setting P2.008. Do not change the auxiliary adjustment as this parameter cannot be reset. Settings: Manually adjust the offset. The function must be enabled by setting P2.008. Do not change the auxiliary adjustment as this parameter cannot be reset. Settings: Cool down the drive to 25°C (77°F) before adjustment. The function must be enabled by setting P2.008. Settings: Offset adjustment value (cannot reset). The function must be enabled by setting P2.008. 8-105 Address: 0422H P4.017 Current encoder (W1 phase) offset adjustment 0423H Default: Factory setting Control mode: Unit: - Setting range: Format:

DEC Data size: Address: 0424H P4.018 Current encoder (W2 phase) offset adjustment 0425H Default: Factory setting Control mode: All Unit: - Setting range: 0 - 32767 Format: DEC Data size: 16-bit Address: 0426H P4.019 IGBT NTC adjustment level (cannot reset) 0427H Default: Factory setting Control mode: All Unit: - Setting range: 1 - 4 Format: DEC Data size: 16-bit Address: 0428H P4.020 Offset adjustment for analog monitor output (Ch1) 0429H Default: 0 Control mode: All Unit: mV Setting range: -800 to 800 Format: DEC Data size: 16-bit