ASDA-B3 Parameters 8 Settings: Y Z U X X: PR triggered when EV1 is off 0: no action 1 - D: execute PR# 51 - 63 Y: PR triggered when EV2 is off 0: no action 1 - D: execute PR# 51 - 63 Z: PR triggered when EV3 is off 0: no action 1 - D: execute PR# 51 - 63 U: PR triggered when EV4 is off 0: no action 1 - D: execute PR# 51 - 63 Settings: Window #3: when you read or write the parameter by any method, the value set in P5.011 does not add 1. Refer to Section 7.2.1 Data array for detailed instructions. 8-129 Address: 05C6H P5.099 PR# triggered by event falling-edge 05C7H Default: 0x0000 Control mode: Unit: - Setting range: Format: HEX Data size:
X PR triggered by EV1 falling-edge Z PR triggered by EV3 falling-edge Y PR triggered by EV2 falling-edge U PR triggered by EV4 falling-edge Address: 05C8H P5.100■ Data array - window #3 for reading and writing 05C9H Default: 0 Control mode: All Unit: - Setting range: -2147483648 to +2147483647 Format: DEC Data size: 32-bit