Delta Electronics — 9.3 MODBUS communication protocol

MODBUS Communication ASDA-B3 LRC and CRC transmission error check The error check used in ASCII mode is LRC (Longitudinal Redundancy Check) and that used in 9 RTU mode is CRC (Cyclical Redundancy Check). See the following details. LRC (ASCII mode): To calculate the LRC value: add all the bytes, round down the carry, and take the two’s complement. For example: 7FH + 03H + 05H + C4H + 00H + 01H = 14CH, round down the carry 1 and take 4CH. The two’s complement of 4CH is B4H . 9-10 Start ‘:’ ‘7’ Slave Address ‘F’ ‘0’ Function ‘3’ ‘0’ ‘5’ Start Data Address ‘C’ ‘4’ ‘0’ ‘0’ Data Number ‘0’ ‘1’ ‘B’ LRC ‘4’ End 1 (0DH) (CR) End 0 (0AH) (LF)