ASDA-B3 Absolute System Descriptions: 1. When the handshake communication starts, the ABSE signal is triggered. 2. After the T s delay time (make sure the signal is on), the functions for DI4, DO2, and DO3 10 are switched to ABSQ, ABSR, and ABSD, respectively. If DI4 was in the high-level state before, it remains in the high-level state when switched to ABSQ (logic high-level signal). DI4, DO2, and DO3 are dual-function DI/DO, which means DI4, DO2, and DO3 share the same DI with ABSQ, ABSR, and ABSD. Pay special attention when switching functions or set the DI/DO to 0 to disable the dual-function of DI/DO. 3.
If DI4 was in the high-level state and switched to ABSQ after the T S delay time, when the controller resets this signal to low level, the new signal is interpreted as the data access command. 4. After the T Q time, the handshake data is ready and the absolute position is sent to ABSD. Now the servo drive turns on the ABSR signal and the controller can access the data. If the controller still cannot detect the ABSR status while it is changing to high level after the maximum T Q time (refer to Figure 10.3.5.1.1), there may be a communication error. 5.
Once the ABSR signal is set to high level, the controller accesses the data, and the ABSQ signal is set to high level to notify the servo drive that data was read. 6. When ABSQ is at high level, ABSR is set to low level after the T N time in order to send the data for the next bit communication. 7. When ABSR is at low level, ABSQ is also set to low level and the servo drive needs to send the data for the next bit communication. 8. Repeat steps 3 and 4. Send the absolute position to ABSD for the next bit communication. 9. Repeat steps 5 to 7. The controller has read and received the data. 10. The third bit data is ready. 11.
After the T R waiting time, if the controller has not read the data and turned on the ABSQ signal, the servo drive sends the ABSW signal (communication error) and stops the handshake communication. 12. When the controller receives the communication error signal, it sets ABSE to low level and prepares to restart the handshake communication. 13. ABSW resumes to low level after the servo drive receives the ABSE signal. 14. The controller resumes communication after the T B time. 15. Repeat step 1. 16. If no error occurs, the controller completes 80 bits (0 - 79) of the handshake communication with the servo drive. DI4, DO2, and DO3 then resume their original functions. Note:
if ABSE is set to low level first and then changed to high level, but ABSW does not resume to high level and the alarm remains on, it means some other errors exist. Check for the following possible warnings: absolute position lost, low battery voltage level, or absolute position overflows. Restart a new communication cycle after those errors have been cleared. 10-19