Delta Electronics — 10.4 List of absolute parameters, DI/DO, and alarms

ASDA-B3 Absolute System 10.4 List of absolute parameters, DI/DO, and alarms Relevant parameters (refer to Chapter 8 for detailed information): 10 Relevant DI/DO (refer to Chapter 8 for detailed information): Relevant alarms (refer to Chapter 12 for detailed information):

10-21 Parameter Function P0.002 Drive status P0.049 Update encoder absolute position P0.050 Absolute coordinate system status P0.051 Encoder absolute position - multiple turns P0.052 Encoder absolute position - pulse number or PUU within single turn P2.069 Absolute encoder P2.070 Read data selection P2.071 Absolute position homing Setting value DI name Setting value DO name 0x1D ABSE When DI.ABSE is on, DI.ABSR triggered by DO2 replaces the DO2 assigned by P2.019. ABSR always output by DO2 When DI.ABSE is on, the DI.ABSQ from DI4 replaces the DI4 function from P2.013. ABSQ always input by DI4 When DI.ABSE is on, DI.ABSD triggered by DO3 replaces the DO3 assigned by P2.020.

ABSD always output by DO3 0x1F ABSC 0x0D ABSW Display Alarm name AL060 Absolute position is lost AL061 Encoder undervoltage AL062 Number of turns for the absolute encoder overflows AL069 Wrong motor type AL072 Encoder overspeed AL073 Encoder memory error AL074 Encoder single-turn absolute position error AL075 Encoder absolute number of turns is in error AL077 Encoder internal error AL079 Encoder parameter error AL07B Encoder memory busy AL07C Command to clear the absolute position is issued when the motor speed is over 200 rpm AL07D Motor stops operating when servo drive power is cycled before AL07C is cleared AL07E Encoder clearing procedure error AL289 Position counter overflows