CANopen Mode ASDA-B3 11.1.3 Parameter settings of CANopen mode Follow these instructions to connect the CANopen controller and the ASDA-B3 servo drive: 11 1. Set CANopen mode: set P1.001 to 0x0C. 2. Set node ID: set the range of P3.000 to 01h - 7Fh. 3. Set P3.001 to 0403h for baud rate as 1 Mbps (Z = 0: 125 Kbps; 1: 250 Kbps; 2: 500 Kbps; 3: 750 Kbps; 4: 1 Mbps). 4. It is suggested to set P3.012 to 0x0100, so the parameters in the following table are non-volatile. 5. It is suggested to enable the dynamic brake function (P1.032 = 0x0000).
11-4 Variables during P3.012.Z = 0 P3.012.Z = 1 Note initialization P1.032 0x0010 EEPROM - P2.035 50331648 EEPROM - P1.047 100 EEPROM - P1.049 0 EEPROM - P1.038 100 EEPROM - P6.001 0 EEPROM - Acc (P1.034) 200 EEPROM Used in PV and PP modes Dec (P1.034) 200 EEPROM Used in PV and PP modes Torque slope 200 EEPROM Used in PT mode (P1.034) P1.044 1 EEPROM - P1.045 1 EEPROM - P1.055 Depending on the motor specifications EEPROM - P5.008 2147483647 EEPROM - P5.009 -2147483648 EEPROM -