CANopen Mode ASDA-B3 11.3.5 Profile Torque Mode In PT (Profile Torque) mode, the controller specifies the torque command and filtering conditions, 11 and the motion command generator of the servo drive plans the torque slope according to these conditions. (6074h) Torque demand value Torque control Servo motor loop Filter P1.007 Torque actual value (6077h) M Velocity actual value (606Ch) Encoder Operation steps: 1. Set OD 6060h to 04h to set the mode as the torque control mode. 2. Set OD 6087h for the torque slope. 3. Set the target torque (OD 6071h) to 0. In torque mode, the servo target torque takes effect once the servo is switched to servo on (Step 4).
Therefore, set the target torque (OD 6071h) to 0 for safety reasons. 4. Set OD 6040h for the control command. Follow these steps. Steps 4.1 and 4.2 are to bring the servo drive's state machine into the ready state. For more details of the state machine, refer to Section 11.2.2.6. 5. Set OD 6071h for the target torque. 11-28 Target torque (6071h) Torque command [%] Trajectory generator Torque slope (6087h) E-Gear ratio 6093h sub2 6093h sub1 Step Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Description 4.1 0 0 1 1 0 Shutdown. 4.2 0 0 1 1 1 Switch on (ready for servo on). 4.3 0 1 1 1 1 Enable operation (servo on).