Delta Electronics — 11.4.3.1 OD 1XXXh communication object group

CANopen Mode ASDA-B3 Example: To set three PDOs (OD 6040h, OD 607Ah, and OD 6060h) in the first group of PDO, the setting 11 is as follows: Object 1800h - 1803h: TPDO communication parameter 11-46 Mapping Data Description parameter setting for received PDO OD 1600 sub0 3 Set 3 PDO mappings. OD 1600 sub1 6040h 00h 10h Mapping control command (6040h), data length is 16-bit OD 1600 sub2 607Ah 00h 20h Mapping target position (607Ah), data length is 32-bit OD 1600 sub3 6060h 00h 08h Mapping mode position (6060h), data length is 8-bit Note The total length is 38h (56-bit) which meets the specification of less than 64-bit.

Index 1800h - 1803h Name Transmit PDO parameter Object code RECORD Data type PDO CommPar Access RW Sub-index 0 Description Largest sub-index supported Data type UNSIGNED8 Access RO PDO mapping No Setting range 5 Default 5 Sub-index 1 Description COB-ID used by PDO Data type UNSIGNED32 Access RW PDO mapping No Setting range UNSIGNED32 Default Default Node-ID: 0 Index 1800h: 180h + Node-ID Index 1801h: 280h + Node-ID Index 1802h: 380h + Node-ID Index 1803h: 480h + Node-ID