ASDA-B3 CANopen Mode Object function: When the error value between the command (PP mode: OD 607Ah; IP mode: OD 60C1h) and the position actual value (OD 6064h) is smaller than this object, and the time is greater than 11 OD 6068h (position window time), Bit 10 of Statusword 6041h outputs once the target is reached. Accepted position range Position Target position PP mode Target position (607Ah) Position window (6067h) IP mode Interpolation data record Position window time (6068h) (60C1h) Statusword target reached (6041h) + Window comparator Position window comparator - Position actual value (6064h) Object 6068h: Position window time Object function:
When the error value between the command (PP mode: OD 607Ah; IP mode: OD 60C1h) and the position actual value (OD 6064h) is smaller than this object, and the time is greater than OD 6068h (position window time), Bit 10 of Statusword 6041h outputs once the target is reached. 11-57 ition not reached Position window Position window Position reached Position not rea Index 6068h Name Position window time Object code VAR Data type UNSIGNED16 Access RW PDO mapping Yes Setting range UNSIGNED16 Default 0 Unit ms