Delta Electronics — 11.4.3.3 OD 6XXXh communication object group

CANopen Mode ASDA-B3 Object 6077h: Torque actual value 11 Object function: This object is the current motor torque feedback percentage. Object 6078h: Current actual value Object function: This object is the current motor current feedback percentage. Object 607Ah: Target position Object function: This object is only available in Profile Position Mode. For more details, refer to Section 11.3.1 Profile Position Mode.

11-62 Index 6077h Name Torque actual value Object code VAR Data type INTEGER16 Access RO PDO mapping Yes Setting range INTEGER16 Default 0 Unit 0.1% Index 6078h Name Current actual value Object code VAR Data type INTEGER16 Access RO PDO mapping Yes Setting range INTEGER16 Default 0 Unit 0.1% Index 607Ah Name Target position Object code VAR Data type INTEGER32 Access RW PDO mapping Yes Setting range INTEGER32 Default 0 Unit PUU