Delta Electronics — 11.4.3.3 OD 6XXXh communication object group

ASDA-B3 CANopen Mode 11 Object 6098h: Homing method Object function: There are a total of 35 homing methods. The 1 st - 16 th homing methods look for the Z pulse; the 17 th - 34 th do not look for the Z pulse; and the 35 th defines the current position as the origin. Method 1: homing on the negative limit switch and Z pulse indicates OD 6099h sub1 Speed during search for switch indicates OD 6099h sub2 Speed during search for zero Starting point 1 Z pulse Negative limit switch 11-67 Sub-index 1 Description E-Gear ratio numerator Data type UNSIGNED32 Access RW PDO mapping Yes Default 1 Corresponding servo parameter P1.044 Note For the E-Gear ratio setting, refer to Section 6.2.5.

Sub-index 2 Description E-Gear ratio denominator Data type UNSIGNED32 Access RW PDO mapping Yes Default 1 Corresponding servo parameter P1.045 Note For the E-Gear ratio setting, refer to Section 6.2.5. Index 6098h Name Homing method Object code VAR Data type INTEGER8 Access RW PDO mapping Yes Setting range 0 - 35 Default 0