CANopen Mode ASDA-B3 Object 60C2h: Interpolation time period 11 Object function: This object only works in IP Mode. The interpolation cycle time is calculated by two objects, OD 60C2h sub1 and OD 60C2h sub2. The calculation is as follows: Interpolation cycle time = 60𝐶2ℎ sub1 Ч 10 60C2h sub2 Example: If you want to set the interpolation cycle time to 2 ms, set OD 60C2h sub1 to 2 and OD 60C2h sub2 to -3.
Interpolation cycle time = 2 Ч 10 −3 = 0.002 𝑠 = 2 𝑚𝑠 11-78 Index 60C2h Name Interpolation time period Object code RECORD Data type UNSIGNED8 Access RW PDO mapping Yes Sub-index 0 Description Number of sub-index Data type UNSIGNED8 Access RO PDO mapping No Setting range 2 Default 2 Sub-index 1 Description Interpolation cycle time constant Data type UNSIGNED8 Access RW PDO mapping Yes Setting range UNSIGNED8 Default 1 Sub-index 2 Description Power of 10 Data type INTEGER8 Access RW PDO mapping Yes Setting range -128 to 63 Default -3