Delta Electronics — 11.5 Diagnostics and troubleshooting

CANopen Mode ASDA-B3 11.5 Diagnostics and troubleshooting This section provides diagnostics and troubleshooting information related to communication or 11 interference with the controller. For information about the servo drive alarms, refer to Chapter 12. 1. The SYNC communication cycle of the controller and servo drive is different Since the jitter of each controller is different, the communication cycle time between the servo drive receiving the Sync and Sync synchronization action is different.

When this happens, increase the error value (T) by adjusting P3.009 and let the servo drive automatically correct the internal timer so it is consistent with the communication cycle of the controller. 2. Clear interference Packets are particularly sensitive to interference in high-speed network communication applications. To achieve fast and high-precision control, the selection of the wire is extremely important. Use shielded cables for the communication wiring, and make sure that the cable shield is firmly connected to the servo drive communication port. Also, ensure the ground wire is properly connected and grounded. 11-82