omron — System Options

System Options The names and locations of these files can be changed by accessing the Custom Save Locations button: Generate AUTO.V2 When selected, an AUTO.V2 file will automatically be generated. If Save Programs and Variables on Controller is enabled, the files will be loaded as part of the AUTO program. Additionally, you can specify a Program to Execute on a Task Number . These will be included in the AUTO program. Save Belt Calibrations When selected, you can identify belt-calibrations in the workspace that will be saved to the controller. These calibrations will be saved into the DISK>D:\ARCHIVE\ folder in a file called BELT.DAT.

The V+ Belt cal- ibration utility can be used to load and access the information. Archive Workspace When enabled, the workspace will be saved on the controller in the DISK>D:\ARCHIVE\ folder. System Options The Edit Options windows provides an interface for enabling one or more of the following startup options: l V+ Module Settings: enables the automatic insertion of a program header when a new V+ program is created. For details, see V+ Module Settings on page 105. l Vision Server: enables the remote vision server access and specify a port number for the vision ACE User's Guide, 3.6.x 18316-000 Rev A Page 104