System Monitor ACE User's Guide, 3.6.x 18316-000 Rev A Page 1118 Parameter Description Amplifier bus voltage (V) The current amplifier bus voltage for the robot. This should operate within the specified min/max warning limits (yellow bars), and never reach the min/max error limits (red bars). If the value drops below the range minimum, this means that the motion is too hard or the AC input voltage is too low; if the value exceeds the range maximum, this means that the motion is too hard or the AC input voltage is too high. Lowering the motion speed (more than the acceleration) can help correct these issues. AC input (V) The current AC input voltage (220 VAC) for the robot.
This should operate within the specified min/max warning limits (yellow bars), and never reach the min/max error limits (red bars). Running out- side or close the limits may create envelope errors. DC input (V) The current DC input voltage (24 VDC) for the robot. This should operate within the specified min/max warning limits (yellow bars), and never reach the min/max error limits (red bars). Base board temperature (°C) The current temperature (°C) for the amp-in-base processor board. This should operate within the specified min/max warning limits (yellow bars), and never reach the min/max error limits (red bars).
Encoder temperature (°C) The current encoder temperature (°C) for the selected motor. This should operate within the specified min/max warning limits (yellow bars), and never reach the min/max error limits (red bars). Amplifier temperature (°C) The current temperature (°C) for the motor amplifier. This should operate within the specified min/max warning limits (yellow bars), and never reach the min/max error limits (red bars). Duty cycle (% limit) The current duty cycle value, as a percentage, for the selected motor. This should operate below the specified max warning limit (yellow bar), and never reach the max error limit (red bar).
Harmonic Drive usage (%) The current usage of the Harmonic Drive, as a percentage of design life, for the selected motor. This should operate below the specified max warning limit (yellow bar), and never reach the max error limit (red bar). If the value is less than 100%, the maximum life for the Harmonic Drive will be extended; if the value exceeds 100%, the maximum life of the Harmonic Drive will be diminished. For example, a value of 150% means the time at which 10% of drives will have failed is 1.5 times shorter than the design life. Peak torque (% max torque) The peak torque, as a percentage based on maximum torque, for the selected motor. This should operate below the specified max