Robot Diagnostics Wizard Test Summary ACE User's Guide, 3.6.x, 18316-000 Rev A Page 1133 Test Description Teach 1st Position Select the start point for the robot motion. The joint positions are shown in the test information/control area. NOTE: The robot power is disabled so it can be manually moved to the desired position. Teach 2nd Position Select the end point for the robot motion. The joint positions are shown in the test information/control area. NOTE: The robot power is disabled so it can be manually moved to the desired position. Move Robot Verifies the robot can safely (and repeatedly) move between two locations within the workcell.
A simple control panel is provided, which is used to Start, Pause, Step, and Stop the robot motion. Verify Digital Inputs Optional test procedure that verifies the digital inputs are properly connected. CAUTION: This test requires an XIO Termination Block. If you do not have it installed, the test may result in damage to your system. Turn On Inputs Set the digital input switches on the XIO Termination Block to the ON position. Confirm Inputs Are On Verifies that the digital inputs are in the ON state. Turn Off Inputs Set the digital input switches on the XIO Termination Block to the OFF position. Confirm Inputs Are Off Verifies that the digital inputs are in the OFF state.
Verify Digital Outputs Optional test procedure that verifies the digital outputs are prop- erly connected. CAUTION: This test requires an XIO Termination Block. If you do not have it installed, the test may result in damage to your system. Confirm Outputs Are On Verifies that the digital outputs can be properly set to the ON state. Confirm Outputs Are Off Verifies that the digital outputs can be properly set to the OFF state.