Overview Overview Establishing OPC communication between devices requires proper configuration of the Microsoft Windows operating system security settings to allow this type of access. The configuration is accomplished using the Distributed Component Object Model (DCOM), which is a Microsoft technology. Due to the distributed archi- tecture of the ACE and SmartVision EX servers, it may be necessary to configure multiple PCs using DCOM, when OPC communication is enabled. This document provides a detailed procedure for configuring these settings using DCOM.

Applicable Products l ACE with OPC license enabled l Third party OPC servers / clients l SmartVision EX running Windows XP embedded l Any PC running Windows XP SP2 Notes The SmartVision EX product has a File Based Write Filter (FBWF) that creates a RAM buffer to protect the operating system from corruption. The FBWF must be disabled before continuing with this procedure. For details on disabling the FBWF, see the Adept SmartVision EX User’s Guide . If you follow this procedure and are still having trouble with OPC communications, it may be useful to tem- porarily disable the Windows Firewall for troubleshooting purposes (consult your Windows operating sys- tem online help for instructions).

In most cases, improper configuration of the Windows Firewall is the root cause for not being able to establish communication between OPC servers and clients. Once you have established communications, you can re-enable the Windows Firewall with the proper exceptions, as described in Step 7: Configure the Windows Firewall to allow exceptions on page 1162 Summary This section provides an summary of the steps you will follow to complete the configuration of DCOM. Each step is detailed in the next section. NOTE: The changes described in this procedure must be made for all computers using OPC com- munications, which includes clients, servers, touch screens, etc. Step 1:

Create a computer name and define the workgroup / domain on page 1139 Step 2: Create matching user accounts and passwords on page 1141 Step 3: Configure the DCOM settings for system-wide security parameters on page 1142 Step 4: Configure the DCOM settings for all computers using OPC on page 1151 Step 5: Configure OpcEnum for all computers using OPC on page 1158 Step 6: Activate the Guest account on page 1160 Step 7: Configure the Windows Firewall to allow exceptions on page 1162 ACE User's Guide, 3.6.x, 18316-000 Rev A Page 1137